The best Human Tumor Protein p53 (TP53) ELISA Kit (CLIA), quick delivery, high quality.
1032 EUR
96 Tests
EKU08927
E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays,E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays,Human proteins, cDNA and human recombinants are used in human reactive ELISA kits and to produce anti-human mono and polyclonal antibodies. Modern humans (Homo sapiens, primarily ssp. Homo sapiens sapiens). Depending on the epitopes used human ELISA kits can be cross reactive to many other species. Mainly analyzed are human serum, plasma, urine, saliva, human cell culture supernatants and biological samples.
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Tumor Protein p53 were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Tumor Protein p53 were tested on 3 different plates, 8 replicates in each plate.CV (%) = SD/meanX100;Intra-Assay: CV
p53, LFS1, TRP53, Li-Fraumeni Syndrome, Cellular tumor antigen p53, Antigen NY-CO-13, Phosphoprotein p53, Tumor suppressor p53
No significant cross-reactivity or interference between Tumor Protein p53 and analogues was observed.
No significant cross-reactivity or interference between Tumor Protein p53 and analogues was observed.
Serum, Plasma, Tissue homogenates, Cell lysates, Cell culture supernates and other biological fluids
This assay has high sensitivity and excellent specificity for detection of Tumor Protein p53
The kit is manufactured at ISO 9001 and ISO 13485 certified facilities.
Use Human Tumor Protein p53 (TP53) ELISA Kit (CLIA) before 8 months
The Stop Solution is acidic. Do not allow to contact skin or eyes.
ELISA Enzyme-linked immunosorbent assays Code 90320007 SNOMED
Signal transduction, Metabolic pathway, Tumor immunity
For research use only. Not for diagnostic procedures.
Short term: 4°C; Long term: see manual.
Double-antibody Sandwich
Homo sapiens (Human)
6-11 Business days
2 hours, 40minutes
Tumor Protein p53
Chemiluminescent
27.4-20000 pg/mL
9.5 pg/mL
Ice packs
tumor